Baltimore County's Dedicated Generac Specialists
The short answer: figure out your peak load, not your square footage. Most Baltimore County homes need a 14–24kW standby generator for whole-home coverage — but the only number that matters is your home's peak electrical demand in watts. Here's the 15-minute method for finding it.
Prefer to talk? (443) 499-2549
Every oversized generator wastes money and every undersized one fails at the worst moment — usually when the AC compressor kicks on mid-outage and the whole unit trips offline. Sizing isn't guesswork, and it isn't square footage. It's a load inventory: what must stay on, how many watts each thing draws, and what surges when motors start.
Two homes with identical floor plans can need different generators. A 2,500 sq ft home in Towson with gas heat needs less than a 2,000 sq ft all-electric home in White Marsh with a heat pump and a hot tub. Here's how to work out yours.
Walk through your home and list everything that must run during an outage, then note each item's running watts (steady draw) and starting watts (the 2–3 second surge when a motor starts). Starting watts are the ones that kill undersized generators.
| Appliance | Typical running watts | Typical starting watts |
|---|---|---|
| Refrigerator / freezer | 150–700 | 1,200–2,200 |
| Central AC, 3-ton | ~3,500 | ~7,500–10,000 |
| Heat pump emergency strips | 10,000–15,000 | 10,000–15,000 |
| Gas furnace fan | 500–800 | 1,200–2,000 |
| Sump pump | 800–1,050 | 1,300–2,150 |
| Well pump | 1,000–2,500 | 3,000–5,000 |
| Electric water heater | 4,000–4,500 | 4,000–4,500 |
| Electric clothes dryer | ~5,000 | ~5,000 |
| Microwave | 1,000–1,500 | 1,000–1,500 |
| Whole-house LED lighting | 300–600 | — |
| TV, computers, phones, chargers | 200–400 | — |
Typical ranges from common spec data — your exact models may differ; confirm against the nameplate or the manufacturer's spec sheet before buying.
Sum the running watts of everything on your must-run list — that's your steady-state load. Then make sure the generator's surge capacity covers the highest simultaneous starting surge (for example, the AC compressor kicking on while the well pump and sump pump are already running). Add 20–25% headroom on top for the loads you forgot and the ones that cycle on unpredictably.
Then decide how much of the house you're backing up:
Essentials-only: fridge, lights, sump pump, furnace fan, phone chargers, a few outlets — roughly 5–8kW of steady load. A 10–14kW standby unit covers this comfortably and costs the least to install.
Managed whole-home: add the AC and dryer to the list, with load-management modules that shed big loads during startup peaks. An 18kW unit with load management handles most Baltimore County homes this way — and it's often the best value per dollar of coverage.
True whole-home: everything on, no compromises, no load shedding. For most homes here that's 22–24kW; large or all-electric homes may need 26kW.
We run this exact calculation free during every site assessment — it's the single most important part of the visit.
1. The surge lesson from Parkville. When the Sept. 3, 2026 outage hit Parkville's Cromwood Coventry neighborhood, residents reported lights cycling on and off before the power dropped — and surging power reportedly damaged appliances and HVAC systems in more than 30 homes. Undersized or surging equipment is exactly what a properly sized, professionally installed standby system with a transfer switch is designed to prevent.
2. Gas heat changes the math. Much of the older suburban corridor — Parkville, Towson, Catonsville, Dundalk — runs on natural gas heat, which means the furnace needs only its blower motor (500–800W) rather than electric resistance heat. A gas-heat home can back up essentials plus central air on 18–22kW; an all-electric home with heat-pump emergency strips can draw 10–15kW on the strips alone and typically needs 24kW+ for true whole-home coverage.
3. Well pumps are the rural sizing trap. Northern county homes in Hereford and Monkton on well water carry one of the nastiest surge loads in residential sizing — a well pump can draw 3,000–5,000 starting watts. If you're on a well, budget for it explicitly; it's the load most often forgotten in online "sizing calculators."
4. Sump pumps are non-negotiable. Homes with basements in low-lying areas — parts of Dundalk, Essex, and Middle River — flood when the power dies during a storm. A sump pump's surge watts (up to ~2,150) plus the risk of basement damage make it a must-run load, and it's one of the strongest arguments for a standby unit that starts itself whether you're home or not.
5. Anything wired into the house needs a permit. Baltimore County requires an electrical permit for standby generators and transfer switches (or an interlock feeding a portable into your panel), and Maryland only lets licensed master electricians pull them. Professional sizing, installation, and permits come as one package with us — start with the free assessment.
Sizing from square footage. Online calculators that ask for your home's square footage are guessing — they can't see your electric dryer, your hot tub, or your heat-pump strips. Two identical floor plans can differ by 8kW of real load.
Forgetting starting watts. The compressor, the well pump, and the sump pump don't draw their nameplate watts when they start — they draw 2–3x. This is the single most common cause of "the generator worked fine until everything kicked on at once."
Sizing for today's outage and forgetting tomorrow's. Homes gain loads — a second fridge, a workshop, an EV charger. That 20–25% buffer isn't waste; it's the difference between a generator that still fits in five years and one that doesn't.
Already narrowed it to Generac? Our Generac-specific sizing guide maps your load to the right Guardian or Protector model.
List what must stay powered, add up their running watts, then make sure the generator also covers starting (surge) watts — motors in AC compressors, well pumps, and sump pumps draw 2–3x their running watts for a few seconds at startup. Add a 20–25% buffer on top. We do this load inventory free during every site assessment, so you don't have to do the math alone.
A typical 3-ton central AC draws about 3,500 running watts but needs roughly 7,500–10,000 watts at compressor startup. Practically, that means central AC is an 18kW-and-up conversation for standby generators, or a smaller unit with load management that sheds the AC during startup peaks. A 10kW unit covers essentials but not central air.
Not a typical one — 10kW covers essential circuits (fridge, lights, sump pump, furnace fan, some outlets) but won't carry central AC, an electric dryer, and an electric water heater at once. True whole-home coverage for most Baltimore County homes lands at 18–24kW.
Both — and starting watts are what trip undersized units. Running watts tell you steady-state load; starting (surge) watts tell you what happens the instant a motor kicks on. The generator must survive the highest simultaneous surge, which is why two homes with the same square footage can need very different generators.
From Towson to Essex, Dundalk to Monkton — wherever you are in the county, a Generac specialist is close by.
24/7 Emergency Repair
A dead generator during a storm is an emergency — and we treat it like one. Call any time, day or night, and a Baltimore County Generac technician will get your backup power back online.
Same-day & after-hours emergency response across Baltimore County.
(443) 499-2549Mon–Sat: 9:00 AM – 5:00 PM · Sun: Emergency Service Only
Free estimates on installations. 24/7 emergency repair. One county, one specialty: Generac.